K9 GUNSHOT IN A BOX Trainer
For a better price—please send an inquiry
Third-Degree Arm Burn
For a better price—please send an inquiry
Second-Degree Burn
SKU:
SW007-L
A self-adhering wound simulation replicating a second-degree burn with blisters — ideal for realistic training scenarios.
For a better price—please send an inquiry
Tags: simulation, wound simulation
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW007-L |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Equipment / Configuration | 1 wound imitation |
Description
This wound simulation is ready to use straight out of the packaging — no additional glue or makeup required. It replicates a second-degree burn with blisters and adheres directly to the moulage actor’s skin. According to the manufacturer, the wound can be transferred from one actor to another without any additional treatment and reused multiple times. If it becomes soiled, simply wash it with warm, soapy water to restore the self-adhesive base to full effectiveness.
Technical Specifications
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW007-L |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Equipment / Configuration | 1 wound imitation |
Similar products
BurnTec Hydrogel Burn Dressing (Military Version)
For a better price—please send an inquiry
| NSN | 6510-43-0015993 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | BurnTec Hydrogel Burn Dressing, Military Version. |
| Kilmės šalis | Poland |
| Gaminio tipas | Medical device |
| Features | Sterile, stable-structure hydrogel dressing designed for burns and other skin injuries; 5 × 5 cm; contains more than 90% water; reinforced with medical-grade non-woven material; provides uniform cooling to the affected area; cooling and soothing effect may last for up to 24 hours; absorbs wound exudate; maintains a moist wound environment; permeable to water vapour and oxygen while providing a barrier against bacteria; does not adhere to the wound; flexible and conforms to body contours; sterile; Class IIb medical device; military version supplied in khaki-coloured packaging. |
| Certificates | FDA cleared; CE. |
| Sterility | Sterile |
| Expiration date | 5 years. |
| Usage | First aid for burns during military and field operations. |
| Warnings | Single-use device. Do not use for prolonged cooling of large-area burns without monitoring body temperature, as there is a risk of hypothermia. |
| Storage | Store in a dry place at room temperature. Protect from freezing. |
| Spalva | Žalia |
| Equipment / Configuration | 1 burn dressing. |
| Dydis | 5x5cm, 6x12cm, 10x10cm, 12x12cm, 12×24, 20x20cm, 10x40cm, 20x40cm, 40×60 cm, Face dressing 30x40cm |
Cannulite-Sim Intravenous Cannulation Training System
For a better price—please send an inquiry
| Manufacturer | Venner Medical International Ltd. |
|---|---|
| Model | Cannulite-Sim IV Cannulation Simulator / IV Puncture Trainer |
| Kilmės šalis | United Kingdom |
| Gaminio tipas | Teaching aid |
| Features | Cannulite-Sim® is a reusable training device designed to develop peripheral intravenous cannulation skills. The device uses visual light-based feedback to help assess cannula positioning during training and enables trainees to develop correct cannulation technique more efficiently.The device is compatible with standard intravenous cannulas and does not require fluids or simulated blood, helping reduce training preparation time. Suitable for use in medical universities, simulation centres, hospitals, and emergency medical services training programmes. |
| Sterility | Non-sterile. |
| Usage | Reusable. Intravenous cannulation and venipuncture training in medical courses and nursing education programmes. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Spalva | Skaidri |
| Equipment / Configuration | Cannulite-Sim® įrenginys, naudojimo instrukcija. Verification Required dėl tikslios komplektacijos. |
Degloving Injury Moulage CS010
For a better price—please send an inquiry
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | CS010-L |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Equipment / Configuration | 1 × self-adhesive skin tear simulation (Skin Tear CS010-L). |
Injured Arm Moulage
For a better price—please send an inquiry
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW015-L |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Sterility | Non-sterile |
| Equipment / Configuration | 1 wound imitation |
Techline Simulated Blood Powder
For a better price—please send an inquiry
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | Simulated blood powder |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Powdered simulated blood for trauma and bleeding simulations; 4.4 oz (~125 g) package; when mixed with water, produces approximately 4–7 L of simulated blood; consistency can be adjusted by varying the amount of water; designed to simulate wounds, cuts, bleeding, blood droplets, and other blood effects; does not leave permanent stains; suitable for use on skin, training manikins, and various surfaces; washable with soap and water; compatible with TOM, TAMI, Hemorrhage Control PTT, and SKEDCO FEBSS systems. |
| Sterility | Non-sterile |
| Usage | Preparation of simulated blood for training scenarios, wound simulations, and medical simulators. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Product dimensions | Powder weight: 4.4 oz ≈ 125 g. |
| Spalva | Raudona |
| Equipment / Configuration | 1 × 4.4 oz (approximately 125 g) container of Techline simulated blood powder. |