TMT Tactical Mechanical Tourniquet
One-handed windlass tourniquet with a 5 cm wide strap and dual-locking mechanism, designed for rapid and reliable control of life-threatening extremity bleeding.
For a better price—please send an inquiry
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| NSN | 6515-01-656-6191 |
|---|---|
| Manufacturer | Safeguard Medical (manufactured by Alphapointe, USA) |
| Model | TMT Tactical Mechanical Tourniquet |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | 2-inch wide strap; dual-locking torsion mechanism; audible locking click; one-handed application; CoTCCC recommended; made in the USA. |
| Certificates | FDA GUDID registration; Berry Compliant version (31-115). |
| Sterility | Non-sterile |
| Expiration date | 7 years |
| Usage | Life-threatening bleeding from an arm or leg when a pressure dressing is insufficient. Tactical medicine, emergency medical services, and occupational safety. |
| Warnings | The tourniquet should only be applied in cases of life-threatening extremity bleeding. The application time must be recorded. It should only be removed by a medical professional. |
| Storage | Store in a dry place and protect from direct sunlight. |
| Product dimensions | Suitable for limbs with a circumference of 14.6–96.5 cm; packaged dimensions: 11.4 × 6.4 × 5.1 cm. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × tourniquet |
Description
The TMT Tactical Mechanical Tourniquet is a windlass-type extremity tourniquet designed to control life-threatening massive extremity bleeding. Its construction features a 2-inch (approximately 5 cm) wide strap, which is wider than that of many conventional tourniquets, helping distribute pressure over a larger area of the limb.
The tourniquet incorporates a dual-locking torsion mechanism, with an audible click confirming that the mechanism has been securely locked. Its design enables rapid application in critical situations, and the tourniquet can be applied with one hand when necessary, making it suitable for self-application.
The TMT is intended for professional use in emergency, tactical, and military medicine and can also be included in bleeding control and first aid kits. The device is registered with the U.S. Food and Drug Administration (FDA) and bears the CE mark.
How does it differ from a CAT?
The TMT uses a wider 2-inch band and a dual-locking torsion-bar mechanism.
Can it be self-applied?
Yes, the design supports one-handed application.
Technical Specifications
| NSN | 6515-01-656-6191 |
|---|---|
| Manufacturer | Safeguard Medical (manufactured by Alphapointe, USA) |
| Model | TMT Tactical Mechanical Tourniquet |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | 2-inch wide strap; dual-locking torsion mechanism; audible locking click; one-handed application; CoTCCC recommended; made in the USA. |
| Certificates | FDA GUDID registration; Berry Compliant version (31-115). |
| Sterility | Non-sterile |
| Expiration date | 7 years |
| Usage | Life-threatening bleeding from an arm or leg when a pressure dressing is insufficient. Tactical medicine, emergency medical services, and occupational safety. |
| Warnings | The tourniquet should only be applied in cases of life-threatening extremity bleeding. The application time must be recorded. It should only be removed by a medical professional. |
| Storage | Store in a dry place and protect from direct sunlight. |
| Product dimensions | Suitable for limbs with a circumference of 14.6–96.5 cm; packaged dimensions: 11.4 × 6.4 × 5.1 cm. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × tourniquet |
Similar products
Blizzard IFAK Blanket BPS47
| NSN | 4240-99-334-1172 |
|---|---|
| Manufacturer | Blizzard Protection Systems (Safeguard Medical) |
| Model | Blizzard IFAK Double-Sided Blanket |
| Kilmės šalis | United Kingdom, United Kingdom |
| Gaminio tipas | Medical device, Medical device |
| Features | 2-layer Reflexcell construction; about 142 g (5 oz); packed at roughly 15 x 11.4 x 3.8 cm; opens to about 198 x 117 cm; TOG 5; windproof and waterproof |
| Certificates | EU and UK declarations of conformity |
| Expiration date | 7 years |
| Usage | Immediate hypothermia prevention in individual first aid kits where space and weight are at a premium. |
| Warnings | The blanket reduces heat loss but does not generate heat. Severe hypothermia requires active warming. |
| Storage | Store in a dry place in the original packaging. |
| Product dimensions | Unfolded approx. 198 x 117 cm (78 x 46 in) |
| Equipment / Configuration | 1 blanket |
Blue disposable nitrile gloves
| Manufacturer | ZARYS |
|---|---|
| Model | Blue disposable nitrile gloves. |
| Kilmės šalis | Poland, Poland |
| Gaminio tipas | Personal protective equipment, Personal protective equipment |
| Features | Latex-free nitrile, blue, single-use. |
| Certificates | EN 455 (1–4), EN ISO 374-1:2016+A1:2018 Type B, EN ISO 374-5 (Virus), EN ISO 21420, Suitable for food contact. |
| Expiration date | 5 years. |
| Usage | Personal protection in medical, emergency medical, and first aid settings. |
| Warnings | Gloves must be changed if damaged and after each patient. |
| Storage | Store dry, protect from direct sunlight and ozone sources. |
| Spalva | Mėlyna |
| Equipment / Configuration | 100 disposable nitrile gloves (50 pairs). |
NIO Infant Intraosseous Access Device
| Manufacturer | PerSys Medical (Safeguard Medical) |
|---|---|
| Model | NIO Infant, stepped needle 14G–18G |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Stepped 14G–18G needle; tactile feedback indicating position within the bone marrow cavity; self-contained device; no exposed needle. |
| Certificates | FDA 510(k) (K190538), ISO 13485 |
| Sterility | Sterile |
| Expiration date | 5 years. |
| Usage | Emergency vascular access in infants when intravenous access cannot be established or is not feasible. |
| Warnings | Intended for use by trained healthcare professionals only. Do not use on fractured or infected bone. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Product dimensions | 11,7 × 4,3 × 3,3 cm. |
| Equipment / Configuration | 1 × sterile NIO Infant™ device, 1 × Fixation Dressing securement dressing, instructions for use. |
Rüsch Adjustable Nasopharyngeal Airway
| NSN | 26 FR, 28 FR |
|---|---|
| Manufacturer | Teleflex (Rüsch) |
| Model | Adjustable Nasopharyngeal Airway |
| Gaminio tipas | Medical device, Medical device |
| Features | Adjustable flange for setting insertion depth; flexible tube; verification required for diameter, length, and material. |
| Sterility | Sterile |
| Usage | Airway management in unconscious or partially conscious patients with an intact gag reflex. |
| Warnings | Do not use if a basilar skull fracture is suspected or in cases of severe facial trauma. The airway should be inserted by a trained person. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Product dimensions | 26 Fr: length – 170 mm, inner diameter (I.D.) – 6.0 mm, outer diameter (O.D.) – 8.7 mm. 28 Fr: length – 170 mm, inner diameter (I.D.) – 6.5 mm, outer diameter (O.D.) – 9.3 mm. |
| Equipment / Configuration | 1 × Rüsch adjustable nasopharyngeal airway + 1 × 5 g sachet of OptiLube lubricant. |
SICH Tourniquet, Blue
| Manufacturer | SICH (Ukraina / Ukraine) |
|---|---|
| Model | SICH Tourniquet, Blue |
| Kilmės šalis | Ukraine, Ukraine |
| Gaminio tipas | Medical device, Medical device |
| Features | Weight: 105 g; length: at least 93 cm; outer strap width: 40 mm ± 2 mm; duralumin components; suitable for limbs with a diameter of 5–40 cm. |
| Certificates | CE; UDI; NATO |
| Sterility | Non-sterile |
| Usage | Life-threatening extremity bleeding — if confirmed as a variant intended for operational use. |
| Warnings | Before including the product in operational medical supplies, its intended use must be confirmed. Training tourniquets must not be used to control real-life bleeding. |
| Storage | Store in a dry place and protect from direct sunlight. |
| Product dimensions | Length: at least 93 cm; outer strap width: 40 mm ± 2 mm; inner strap width: 25 mm ± 2 mm. |
| Spalva | Mėlyna |
| Equipment / Configuration | 1 turniket |