Israeli Trauma & Amputation Bandage FCP-09, 8″ (20 cm)
The largest dressing in this series, designed for large abdominal wounds, amputations, and blast-related injuries.
For a better price—please send an inquiry
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| NSN | 6510-01-532-6656 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | FCP-09, 8″ (20 cm) |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | Sterile 12 × 12-inch pad; integrated pressure applicator that can be bypassed when required; elastic bandage; “Stop-N-Go” fixation; double vacuum-sealed packaging; 8-year shelf life. |
| Certificates | FDA 510(k) cleared; FDA-cleared as a non-pneumatic tourniquet. |
| Sterility | Sterile |
| Expiration date | 8 years. |
| Usage | Abdominal wounds and eviscerations, limb amputations, blast injuries, and extensive burns. Single-use. |
| Warnings | Single-use device. In cases of evisceration, exposed organs must not be compressed or pushed back into the abdominal cavity. Immediate medical attention is required. |
| Storage | Store in a dry place in the original double vacuum-sealed packaging. |
| Product dimensions | Bandage width: 20 cm; length: 190 cm; sterile pad: 30 × 30 cm. |
| Spalva | Balta, Žalia |
| Equipment / Configuration | 1 × sterile FCP-09 trauma and amputation dressing in individual double vacuum-sealed packaging. |
Description
FCP-09 is a sterile large-area trauma dressing designed to cover large and complex wounds and help control bleeding. It is intended for situations where a standard-sized dressing does not provide sufficient coverage, such as abdominal wounds, evisceration, extensive burns, or traumatic amputations.
The large 12 × 12 inch (approximately 30 × 30 cm) sterile pad provides coverage for a greater area of damaged tissue and helps protect the wound until further medical treatment can be provided.
The integrated pressure applicator allows the dressing to be adapted according to the type of injury. When bleeding control is required, such as in cases of traumatic amputation, the pressure applicator can be used to apply direct pressure to the wound area.
In situations where direct pressure is inappropriate or could cause additional injury, such as in cases of evisceration, the pressure applicator can be bypassed, allowing the dressing to cover and protect the wound without applying pressure.
FCP-09 is supplied in double vacuum-sealed packaging, which helps protect the sterile dressing until use and allows it to be stored compactly in a first aid or trauma kit. Its large coverage area and the ability to adapt the dressing technique to the specific injury make the FCP-09 suitable for emergency medical, tactical medicine, and rescue situations where rapid and appropriate protection of a large wound area is required.
Can it be used with exposed organs?
Yes – the manufacturer states the pressure bar can be bypassed to cover the wound without applying pressure.
What is the pad size?
12 x 12 inches.
Technical Specifications
| NSN | 6510-01-532-6656 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | FCP-09, 8″ (20 cm) |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | Sterile 12 × 12-inch pad; integrated pressure applicator that can be bypassed when required; elastic bandage; “Stop-N-Go” fixation; double vacuum-sealed packaging; 8-year shelf life. |
| Certificates | FDA 510(k) cleared; FDA-cleared as a non-pneumatic tourniquet. |
| Sterility | Sterile |
| Expiration date | 8 years. |
| Usage | Abdominal wounds and eviscerations, limb amputations, blast injuries, and extensive burns. Single-use. |
| Warnings | Single-use device. In cases of evisceration, exposed organs must not be compressed or pushed back into the abdominal cavity. Immediate medical attention is required. |
| Storage | Store in a dry place in the original double vacuum-sealed packaging. |
| Product dimensions | Bandage width: 20 cm; length: 190 cm; sterile pad: 30 × 30 cm. |
| Spalva | Balta, Žalia |
| Equipment / Configuration | 1 × sterile FCP-09 trauma and amputation dressing in individual double vacuum-sealed packaging. |
Similar products
Blue Nitrile Disposable Gloves
| Manufacturer | ZARYS International Group Sp. z o.o |
|---|---|
| Model | Black Disposable Nitrile Gloves |
| Kilmės šalis | Poland |
| Gaminio tipas | Personal protective equipment |
| Features | Material – nitrile (NBR, acrylonitrile-butadiene rubber); colour – black; size – L; powder-free; non-sterile; single-use; natural rubber latex-free; ambidextrous – suitable for both right and left hands; chlorinated inner surface; micro-textured outer surface; textured fingertips; beaded cuff; AQL 1.0; Class I medical device; Category III personal protective equipment (PPE); Type B; compliant with EN 455 and EN ISO 374 requirements; suitable for food contact; shelf life – 5 years; package contains 100 gloves (50 pairs). |
| Certificates | PPE Category III, Type B; AQL 1.0; EN 455-1, EN 455-2, EN 455-3, EN 455-4; EN ISO 374-1, -2, -4, -5; EN ISO 21420; ASTM F1671; ASTM D6978; ASTM D6319; EN ISO 13485; EN ISO 14971; EN ISO 10993 series. Also declared suitable for food contact in accordance with EC 1935/2004 and EU 10/2011. |
| Expiration date | 5 years |
| Usage | Personal protection in medical, emergency medical, and first aid settings. |
| Warnings | Gloves must be changed if damaged and after each patient. |
| Storage | Store dry, protect from direct sunlight and ozone sources. |
| Product dimensions | Length – min. 240 mm; palm width – 110 ± 10 mm. |
| Spalva | Juoda |
| Equipment / Configuration | 100 vnt. disposable nitrile gloves (50 pairs) |
SAM XT Extremity Tourniquet, Hi-Viz Blue
| Manufacturer | SAM Medical Products |
|---|---|
| Model | SAM XT600 Extremity Tourniquet, Hi-Viz Blue |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | TRUFORCE buckle with automatic locking; TRUFLEX plate; metal windlass rod; time strap; limb circumference range: 14.6–82.6 cm; weight: 108 g ± 5 g. |
| Certificates | MIL-STD-810G; ISO 13485:2016 MDSAP; EN ISO 13485:2016. |
| Sterility | Non-sterile |
| Usage | Life-threatening extremity bleeding. Emergency medical and rescue services where high visibility is important. |
| Warnings | Apply only in cases of life-threatening extremity bleeding. Record the application time on the time strap. |
| Storage | Store in a dry place and protect from prolonged exposure to ultraviolet (UV) radiation. |
| Spalva | Mėlyna |
| Equipment / Configuration | 1 × SAM® XT XT600-BL-EN Hi-Viz Blue tourniquet with metal windlass, TRUFORCE™ buckle, Precision Strap, and time recording strap; individually packaged in polyolefin film. |
SICH Tourniquet, Black
| NSN | 6515-61-017-3370 |
|---|---|
| Manufacturer | SICH (Ukraina / Ukraine) |
| Model | SICH Tourniquet black |
| Kilmės šalis | Ukraine |
| Gaminio tipas | Medical device |
| Features | Weight: 105 g; length: at least 93 cm; outer strap width: 40 mm ± 2 mm; inner strap width: 25 mm ± 2 mm; duralumin components; suitable for limbs with a diameter of 5–40 cm. |
| Certificates | NATO NSN; EU compliance. |
| Sterility | Non-sterile |
| Usage | Life-threatening bleeding from an arm or leg. Military and civilian tactical medicine. |
| Warnings | Apply only in cases of life-threatening extremity bleeding. The application time must be recorded. |
| Storage | Store in a dry place and protect from direct sunlight. |
| Product dimensions | Length: ≥93 cm; outer strap width: 40 ± 2 mm; inner strap width: 25 ± 2 mm. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × SICH tourniquet, instructions for use. |
SWAT-T Elastic Tourniquet
| Manufacturer | Safeguard Medical Technologies Ltd. |
|---|---|
| Model | SWAT-T Tourniquet |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | Dimensions: 10 × 137 cm (4″ × 54″); weight: approximately 113 g (4 oz); folded dimensions: approximately 11 × 7.6 cm; pressure indicator pattern; free from natural rubber latex; no mechanical components. |
| Certificates | Biocompatibility tested; MDR Declaration of Conformity. |
| Sterility | Non-sterile. |
| Expiration date | 10 years |
| Spalva | Juoda |
| Product dimensions | 142.2 × 10.2 cm (unstretched) |
| Equipment / Configuration | 1 × SWAT-T™ elastic tourniquet (black) |
| Usage | Bleeding control when a windlass tourniquet is unsuitable due to limb size. Can also be used as a pressure dressing or elastic bandage. |
| Warnings | When applied as a tourniquet, the application time must be recorded. Correct application technique is essential; appropriate training is recommended. |
| Storage | Store dry, protect from direct sunlight and ozone sources. |
Triangular Bandage, Black
| Manufacturer | NOBAMED Paul Danz AG |
|---|---|
| Model | Black Triangular Cloth Bandage. |
| Kilmės šalis | Germany |
| Gaminio tipas | Medical device |
| Features | The triangular cloth bandage is a versatile first aid item used to support an injured arm, immobilise fractures and dislocations, and secure dressings or splints. The soft viscose fabric is comfortable against the skin, durable, and easy to fold into different configurations depending on the type of injury.The black colour makes it particularly suitable for tactical medicine and use by military, police, and rescue services. The triangular bandage complies with DIN 13168 and is suitable for professional and individual first aid kits. |
| Certificates | Complies with DIN 13168 requirements; UDI labelled; compliant with EU MDR 2017/745. |
| Sterility | Non-sterile |
| Expiration date | 8 years from the date of manufacture. |
| Usage | Arm sling, securing dressings and splints, and improvised solutions in first aid situations. |
| Warnings | The triangular bandage is not intended as a primary bleeding control device. In cases of life-threatening bleeding, use a tourniquet or pressure dressing. |
| Storage | Store in a dry place in the original packaging. |
| Product dimensions | 96 × 96 × 136 cm. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × triangular cloth bandage in individual packaging. |