Xtract SR Casualty Evacuation Stretcher
Lightweight fabric stretcher weighing just 1 kg, designed to safely transport a casualty weighing up to 300 kg. The design allows the stretcher to be rapidly deployed and the casualty positioned within approximately 30 seconds.
For a better price—please send an inquiry
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| NSN | 6530-99-315-5529 |
|---|---|
| Manufacturer | TSG Associates LLP |
| Model | Xtract SR Stretcher |
| Kilmės šalis | United Kingdom |
| Gaminio tipas | Medical device |
| Features | Weight: approximately 1 kg; load capacity: up to 300 kg; casualty positioning in approximately 30 seconds; Duralite fabric; drawcord and elastic securing system; graphical positioning markings; NSN 6530-99-315-5529. |
| Sterility | Non-sterile |
| Usage | Casualty evacuation from hazardous areas, including dragging, carrying, and transferring during military, rescue, and tactical operations. |
| Warnings | Inspect the condition of the fabric and seams before use. Do not exceed the manufacturer’s specified load capacity. Casualty handling and transfer should only be performed by trained personnel. |
| Storage | Store in a dry place, folded in the original carrying case. |
| Product dimensions | Unfolded stretcher dimensions: approximately 2500 × 900 mm (250 × 90 cm). |
| Spalva | Juoda |
| Equipment / Configuration | 1 × Xtract™ SR Stretcher textile evacuation stretcher. |
Description
Xtract SR is an ultra-lightweight and compact evacuation stretcher designed for situations where both load capacity and the ability to carry essential evacuation equipment at all times are important. Weighing only 1 kg, the stretcher is manufactured from durable Duralite fabric and, despite its low weight and compact design, can support loads of up to 300 kg.
When folded, the stretcher takes up minimal space, making it easy to carry and quick to deploy when emergency casualty evacuation is required. Clear graphical markings on the stretcher help ensure correct casualty positioning, while the integrated drawcord allows the stretcher to wrap around the body and adapt to different body sizes.
This design is particularly useful when evacuating smaller casualties or individuals with limb loss. The elasticated closure system helps keep the stretcher wrapped securely around the casualty without restricting breathing.
With its low weight, high load capacity, and design adapted to a variety of evacuation scenarios, Xtract SR is a practical solution for emergency medical, tactical medicine, rescue, and other teams that require an evacuation device that is both reliable and readily accessible when needed.
What does it weigh?
About 1 kg.
What is the load capacity?
Up to 300 kg.
Can it be shortened?
Yes, the drawcord adapts it to smaller casualties.
Technical Specifications
| NSN | 6530-99-315-5529 |
|---|---|
| Manufacturer | TSG Associates LLP |
| Model | Xtract SR Stretcher |
| Kilmės šalis | United Kingdom |
| Gaminio tipas | Medical device |
| Features | Weight: approximately 1 kg; load capacity: up to 300 kg; casualty positioning in approximately 30 seconds; Duralite fabric; drawcord and elastic securing system; graphical positioning markings; NSN 6530-99-315-5529. |
| Sterility | Non-sterile |
| Usage | Casualty evacuation from hazardous areas, including dragging, carrying, and transferring during military, rescue, and tactical operations. |
| Warnings | Inspect the condition of the fabric and seams before use. Do not exceed the manufacturer’s specified load capacity. Casualty handling and transfer should only be performed by trained personnel. |
| Storage | Store in a dry place, folded in the original carrying case. |
| Product dimensions | Unfolded stretcher dimensions: approximately 2500 × 900 mm (250 × 90 cm). |
| Spalva | Juoda |
| Equipment / Configuration | 1 × Xtract™ SR Stretcher textile evacuation stretcher. |
Similar products
Israeli Emergency Bandage FCP-02, 6″ (15 cm)
| NSN | 6510-01-492-2275 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | FCP-02, 6″ (15 cm) |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | Sterile 15 × 23 cm non-adherent pad; 165 cm elastic bandage; integrated pressure applicator; “Stop-N-Go” fixation; application sleeve for self-application; 8-year shelf life. |
| Certificates | NSN 6510-01-492-2275 |
| Sterility | Sterile |
| Expiration date | 8 years. |
| Usage | Larger wounds, thigh and torso bleeding, and minor amputations. Military and civilian first aid. Single-use. |
| Warnings | Single-use device. Do not use if the packaging is damaged or the product has expired. |
| Storage | Store in a dry place in the original vacuum-sealed packaging. |
| Product dimensions | Bandage width: 15 cm; length: 165 cm; pad dimensions: 15 × 23 cm. |
| Equipment / Configuration | 1 × sterile 6″ (15 cm) Emergency Bandage® FCP02 in vacuum-sealed packaging. |
Israeli Trauma & Amputation Bandage FCP-09, 8″ (20 cm)
| NSN | 6510-01-532-6656 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | FCP-09, 8″ (20 cm) |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | Sterile 12 × 12-inch pad; integrated pressure applicator that can be bypassed when required; elastic bandage; “Stop-N-Go” fixation; double vacuum-sealed packaging; 8-year shelf life. |
| Certificates | FDA 510(k) cleared; FDA-cleared as a non-pneumatic tourniquet. |
| Sterility | Sterile |
| Expiration date | 8 years. |
| Usage | Abdominal wounds and eviscerations, limb amputations, blast injuries, and extensive burns. Single-use. |
| Warnings | Single-use device. In cases of evisceration, exposed organs must not be compressed or pushed back into the abdominal cavity. Immediate medical attention is required. |
| Storage | Store in a dry place in the original double vacuum-sealed packaging. |
| Product dimensions | Bandage width: 20 cm; length: 190 cm; sterile pad: 30 × 30 cm. |
| Spalva | Balta, Žalia |
| Equipment / Configuration | 1 × sterile FCP-09 trauma and amputation dressing in individual double vacuum-sealed packaging. |
SAM Junctional Tourniquet for Inguinal and Axillary Bleeding
| NSN | 6515-01-618-7475 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM Junctional Tourniquet (SJT) |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Savvybės | AUTOSTOP buckle with audible confirmation at 150 N; 2 Target Compression Devices (TCDs); TCD extender; hand pump with auxiliary strap; application in less than 25 seconds. |
| Certificates | DA 510(k) K131561; EN ISO 13485:2016; ISO 13485:2016/MDSAP. |
| Sterility | Non-sterile |
| Product dimensions | Packed dimensions: 22.5 × 12.1 × 12.1 cm. |
| Usage | Bleeding from the groin or axillary regions; pelvic fracture immobilisation. Tactical medicine, emergency medical services, and military medicine. |
| Warnings | For use by trained professionals. Record the application time. Do not exceed the manufacturer’s specified application duration. |
| Storage | Store in a dry place in the original packaging. Protect the compression devices from puncture damage. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × SJT belt, 2 × Target Compression Devices (TCDs), 1 × TCD extender, 1 × hand pump, 1 × auxiliary strap, 1 × carrying case, instructions for use. |
SICH Tourniquet, Blue
| Manufacturer | SICH (Ukraina / Ukraine) |
|---|---|
| Model | SICH Tourniquet, Blue |
| Kilmės šalis | Ukraine |
| Gaminio tipas | Medical device |
| Features | Weight: 105 g; length: at least 93 cm; outer strap width: 40 mm ± 2 mm; duralumin components; suitable for limbs with a diameter of 5–40 cm. |
| Certificates | CE; UDI; NATO |
| Sterility | Non-sterile |
| Usage | Life-threatening extremity bleeding — if confirmed as a variant intended for operational use. |
| Warnings | Before including the product in operational medical supplies, its intended use must be confirmed. Training tourniquets must not be used to control real-life bleeding. |
| Storage | Store in a dry place and protect from direct sunlight. |
| Product dimensions | Length: at least 93 cm; outer strap width: 40 mm ± 2 mm; inner strap width: 25 mm ± 2 mm. |
| Spalva | Mėlyna |
| Equipment / Configuration | 1 turniket |
Silk Tearable Adhesive Tape
| Manufacturer | ZARYS International Group sp. z o.o. sp.k |
|---|---|
| Model | Silk-Type Tearable Adhesive Tape. |
| Kilmės šalis | Poland |
| Gaminio tipas | Medical device |
| Features | The tape is made of rayon, wound onto a roll, and coated with an acrylic adhesive. The serrated edges allow the tape to be torn both lengthwise and crosswise without scissors. It is breathable and permeable to water vapour, flexible, conforms to body contours, and is hypoallergenic. The manufacturer specifies it for securing and stabilising drains, catheters, medical tubing, and non-adhesive primary dressings. |
| Certificates | EU MDR 2017/745 compliance |
| Sterility | Non-sterile |
| Expiration date | 3 years |
| Usage | Single-use. Securing dressings, cannulas, tubing, and splints in first aid and medical practice. |
| Warnings | Not suitable for patients with an allergy to medical adhesive. Do not apply to damaged or irritated skin. |
| Storage | Store in a dry place at room temperature. |
| Product dimensions | 5 cm × 9,14 m |
| Spalva | Balta |
| Equipment / Configuration | 1 × silk-type medical adhesive tape, 5 cm × 9.14 m, white, wound on a roll. |