BurnTec Hydrogel Burn Dressing
Sterile, non-adherent hydrogel dressing designed to cool burns, protect the affected area, and absorb and retain wound exudate within the hydrogel structure.
For a better price—please send an inquiry
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| Manufacturer | PerSys Medical (Safeguard Medical) |
|---|---|
| Model | BurnTec Hydrogel Burn Dressing |
| Kilmės šalis | Poland, Poland |
| Gaminio tipas | Medical device, Medical device |
| Features | Hydrogel composed of natural and synthetic polymers; sterile and non-adherent; absorbs wound exudate and bacteria into the gel; provides cooling for up to 24 hours; non-woven backing prevents the gel from leaking. |
| Sterility | Sterile |
| Certificates | FDA cleared; ISO 13485 certified. |
| Expiration date | 3 years. |
| Usage | First aid for thermal, chemical, and electrical burns, as well as abrasions. Emergency medical services, occupational safety, and military medicine. |
| Warnings | Single-use device. Do not use for prolonged cooling of large-area burns without monitoring body temperature, as there is a risk of hypothermia. Deep or extensive burns require medical treatment. |
| Storage | Store in a dry place at room temperature. Protect from freezing. |
| Spalva | Skaidri |
| Equipment / Configuration | hydrogel thickness: approximately 3.5 mm. |
| Dydis | 5x5cm, 6x12cm, 10x10cm, 12x12cm, 12x24cm, 20x20cm, 10x40cm, 20x40cm, 40x60cm, Face dressing 30x40cm, Face dressing 40x60cm |
Description
First aid for burns is primarily based on cooling the affected area and protecting it from external exposure. The BurnTec hydrogel burn dressing is designed to perform both functions simultaneously.
The dressing hydrogel consists of an aqueous composition of natural and synthetic polymers, with its structure formed using electron beam technology. The medical-grade non-woven backing helps retain the hydrogel within the dressing and prevents it from running off the affected area, allowing the dressing to remain securely in place and ensuring even contact between the gel and the burn.
The hydrogel helps cool damaged tissue, maintains a moist wound environment, and provides a soothing effect. According to the manufacturer, the cooling and soothing effect may last for up to 24 hours.
Thanks to its design, the BurnTec dressing is a practical solution for providing first aid for burns when it is important to begin cooling the affected area quickly, protect it, and create suitable conditions for further wound care.
Does the dressing stick to the wound?
No, it is non-adherent.
How long does it cool?
The manufacturer states up to 24 hours.
Is it suitable for chemical burns?
The chemical must first be irrigated away per protocol.
Technical Specifications
| Manufacturer | PerSys Medical (Safeguard Medical) |
|---|---|
| Model | BurnTec Hydrogel Burn Dressing |
| Kilmės šalis | Poland, Poland |
| Gaminio tipas | Medical device, Medical device |
| Features | Hydrogel composed of natural and synthetic polymers; sterile and non-adherent; absorbs wound exudate and bacteria into the gel; provides cooling for up to 24 hours; non-woven backing prevents the gel from leaking. |
| Sterility | Sterile |
| Certificates | FDA cleared; ISO 13485 certified. |
| Expiration date | 3 years. |
| Usage | First aid for thermal, chemical, and electrical burns, as well as abrasions. Emergency medical services, occupational safety, and military medicine. |
| Warnings | Single-use device. Do not use for prolonged cooling of large-area burns without monitoring body temperature, as there is a risk of hypothermia. Deep or extensive burns require medical treatment. |
| Storage | Store in a dry place at room temperature. Protect from freezing. |
| Spalva | Skaidri |
| Equipment / Configuration | hydrogel thickness: approximately 3.5 mm. |
| Dydis | 5x5cm, 6x12cm, 10x10cm, 12x12cm, 12x24cm, 20x20cm, 10x40cm, 20x40cm, 40x60cm, Face dressing 30x40cm, Face dressing 40x60cm |
Similar products
Cosinuss c-med alpha In-Ear Vital Signs Sensor
| Manufacturer | cosinuss GmbH |
|---|---|
| Model | c-med° alpha In-Ear Sensor |
| Kilmės šalis | Germany, Germany |
| Gaminio tipas | Medical device, Medical device |
| Features | 8.6 g; measures SpO2, pulse rate and body temperature; red, infrared and green PPG signals; perfusion index and quality indicator; 3-axis accelerometer; Bluetooth 5.0; about 24 h battery, about 1 h charge |
| Certificates | EN ISO 80601-2-61; CE IIa class |
| Sterility | Non-sterile |
| Expiration date | 2 years. |
| Usage | Reusable. Continuous monitoring of vital signs during triage, patient transport, postoperative care, and remote monitoring. |
| Warnings | The device supplements but does not replace clinical assessment. Measurement accuracy may be affected by movement, poor perfusion, and incorrect sensor placement. |
| Storage | Store in a dry place at room temperature; recharge regularly according to the manufacturer’s instructions. |
| Product dimensions | Sensor: 55 mm in length; weight: 6.5 g. |
Israeli Emergency Bandage FCP-02, 6″ (15 cm)
| NSN | 6510-01-492-2275 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | FCP-02, 6″ (15 cm) |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Sterile 15 × 23 cm non-adherent pad; 165 cm elastic bandage; integrated pressure applicator; “Stop-N-Go” fixation; application sleeve for self-application; 8-year shelf life. |
| Certificates | NSN 6510-01-492-2275 |
| Sterility | Sterile |
| Expiration date | 8 years. |
| Usage | Larger wounds, thigh and torso bleeding, and minor amputations. Military and civilian first aid. Single-use. |
| Warnings | Single-use device. Do not use if the packaging is damaged or the product has expired. |
| Storage | Store in a dry place in the original vacuum-sealed packaging. |
| Product dimensions | Bandage width: 15 cm; length: 165 cm; pad dimensions: 15 × 23 cm. |
| Equipment / Configuration | 1 × sterile 6″ (15 cm) Emergency Bandage® FCP02 in vacuum-sealed packaging. |
SAM Pelvic Sling II (Black)
| Manufacturer | SAM Medical Products |
|---|---|
| Model | SAM Pelvic Sling II, Standard (Black) |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Patented AUTOSTOP buckle at 150 N; one-piece design; waist circumference: 81–127 cm (32–50 in). |
| Certificates | FDA Listed |
| Usage | Immobilization of unstable pelvic ring fractures in civilian emergency medical services and hospital settings. Single-use. |
| Warnings | Intended for use by trained professionals. The sling should be positioned over the greater trochanters. After application, circulation in the extremities must be monitored. |
| Storage | Store in a dry place in the original packaging. |
| Product dimensions | Standard size: waist circumference 81–127 cm (32–50 in). |
| Spalva | Juoda |
| Equipment / Configuration | 1 × pelvic sling. |
SAM ThoraSite chest cavity needle decompression system
| NSN | 6515-01-655-9514 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM ThoraSite, 1-pack |
| Country of origin | USA |
| Product type | Medical Device |
| Features | Anatomical landmarking template; helps identify the correct intercostal space; supplied individually (1 unit). |
| Certificates | FDA |
| Sterile | Anatomical landmarking template; helps identify the correct intercostal space; supplied individually (1 unit). |
| Expiration date | 5 years |
| Usage | Identification of needle decompression and lateral thoracostomy sites in emergency, tactical, and military medical settings. |
| Warnings | The device is intended for use by trained professionals and does not replace clinical assessment. Needle decompression should only be performed in accordance with current protocols. |
| Storage | Store in a dry place in the original packaging. |
| Equipment / Configuration | 1pcs. |
Tvarstis Kraujavimui Stabdyti ”ChitoGauze® XR Pro” Safeguard
| NSN | 6510-01-591-7740 |
|---|---|
| Manufacturer | Tricol Biomedical |
| Model | ChitoGauze XR Pro (Safeguard Medical distribution code PDF130) |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Chitosan acetate-coated polyester and viscose gauze; X-ray detectable thread; Z-fold configuration; dimensions: 3″ × 4 yards (7.6 cm × 366 cm); CoTCCC approved; gamma sterilised. |
| Certificates | FDA 510(k) clearance (K153582); BAA compliant; TAA compliant. |
| Sterility | Sterile |
| Expiration date | 66 months |
| Usage | Single-use. Packing of deep wounds where a tourniquet cannot be applied, including the neck, axilla, and groin areas. Control of severe extremity bleeding when used in conjunction with a pressure dressing. |
| Warnings | For temporary external use only. Do not use in body cavities or on the eyes. The gauze should be removed by a healthcare professional. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Product dimensions | 7,5 cm × 3,7 m (3″ × 4 yd) |
| Spalva | Balta |
| Equipment / Configuration | 1 × sterile Z-fold ChitoGauze® XR Pro haemostatic gauze in vacuum-sealed packaging. |