SAM ThoraSite chest cavity needle decompression system
A device that helps quickly and accurately identify the anatomical landmarks required to perform needle decompression and thoracostomy.
For a better price—please send an inquiry
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| NSN | 6515-01-655-9514 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM ThoraSite, 1-pack |
| Country of origin | USA |
| Product type | Medical Device |
| Features | Anatomical landmarking template; helps identify the correct intercostal space; supplied individually (1 unit). |
| Certificates | FDA |
| Sterile | Anatomical landmarking template; helps identify the correct intercostal space; supplied individually (1 unit). |
| Expiration date | 5 years |
| Usage | Identification of needle decompression and lateral thoracostomy sites in emergency, tactical, and military medical settings. |
| Warnings | The device is intended for use by trained professionals and does not replace clinical assessment. Needle decompression should only be performed in accordance with current protocols. |
| Storage | Store in a dry place in the original packaging. |
| Equipment / Configuration | 1pcs. |
Description
Needle decompression is an urgent, life-saving procedure performed when tension pneumothorax is suspected. In such situations, every second counts, but accuracy is equally critical. One of the most common causes of procedure failure is inaccurate selection of the puncture site.
Under stress, in low-visibility environments, or when working in confined spaces, identifying anatomical landmarks can be challenging. Counting intercostal spaces takes time, and an error can result in the procedure being performed in the wrong location.
SAM ThoraSite™ is designed to help healthcare professionals quickly and accurately identify the recommended needle decompression site. The device acts as an anatomical landmark template, helping to identify the correct intercostal space and reduce the risk of performing the procedure too high or too low.
Does this replace training?
No – the device assists, but the procedure must be performed by a trained professional.
What procedure is it for?
Needle decompression and lateral thoracostomy.
Technical Specifications
| NSN | 6515-01-655-9514 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM ThoraSite, 1-pack |
| Country of origin | USA |
| Product type | Medical Device |
| Features | Anatomical landmarking template; helps identify the correct intercostal space; supplied individually (1 unit). |
| Certificates | FDA |
| Sterile | Anatomical landmarking template; helps identify the correct intercostal space; supplied individually (1 unit). |
| Expiration date | 5 years |
| Usage | Identification of needle decompression and lateral thoracostomy sites in emergency, tactical, and military medical settings. |
| Warnings | The device is intended for use by trained professionals and does not replace clinical assessment. Needle decompression should only be performed in accordance with current protocols. |
| Storage | Store in a dry place in the original packaging. |
| Equipment / Configuration | 1pcs. |
Similar products
Israeli Emergency Bandage FCP-02, 6″ (15 cm)
| NSN | 6510-01-492-2275 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | FCP-02, 6″ (15 cm) |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Sterile 15 × 23 cm non-adherent pad; 165 cm elastic bandage; integrated pressure applicator; “Stop-N-Go” fixation; application sleeve for self-application; 8-year shelf life. |
| Certificates | NSN 6510-01-492-2275 |
| Sterility | Sterile |
| Expiration date | 8 years. |
| Usage | Larger wounds, thigh and torso bleeding, and minor amputations. Military and civilian first aid. Single-use. |
| Warnings | Single-use device. Do not use if the packaging is damaged or the product has expired. |
| Storage | Store in a dry place in the original vacuum-sealed packaging. |
| Product dimensions | Bandage width: 15 cm; length: 165 cm; pad dimensions: 15 × 23 cm. |
| Equipment / Configuration | 1 × sterile 6″ (15 cm) Emergency Bandage® FCP02 in vacuum-sealed packaging. |
Israeli Emergency Bandage FCP-03, 4″ (10 cm), White
| NSN | 6510-01-660-2969 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | FCP-03, 4″ (10 cm), white |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Sterile non-adherent pad; integrated pressure applicator; white elastic bandage; closure bar; vacuum-sealed packaging; 8-year shelf life. |
| Certificates | FDA 510(k) cleared; FDA-cleared as a non-pneumatic tourniquet. |
| Sterility | Sterile |
| Expiration date | 8 years. |
| Usage | Bleeding control and wound coverage in emergency medical services, occupational safety, and civilian first aid situations. |
| Warnings | Single-use device. Do not use if the packaging is damaged. Medical evaluation by a healthcare professional is required. |
| Storage | Store in a dry place in the original vacuum-sealed packaging. |
| Product dimensions | Bandage width: 10 cm; length: 160 cm; sterile pad: 10 × 18 cm. |
| Spalva | Balta |
| Equipment / Configuration | 1 × sterile FCP-03 bandage in individual vacuum-sealed packaging. |
NIO Adult Intraosseous Access Device (12 years and over)
| NSN | 6515-01-667-2884 |
|---|---|
| Manufacturer | PerSys Medical (Safeguard Medical) |
| Model | NIO Adult, 15G x 25 mm |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | 15G, 25 mm needle; automatic deployment; access in less than 10 seconds; no exposed needle; protection against accidental activation; 5-year shelf life. |
| Certificates | FDA 510(k) K142086, ISO 13485 |
| Sterility | Sterile |
| Expiration date | 5 years |
| Usage | Emergency vascular access for adults and children aged 12 years and older when intravenous access cannot be established or is not feasible. Single-use. |
| Warnings | For use by trained healthcare professionals only. Do not use in a fractured or infected bone, or in a limb where intraosseous access has already been attempted. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Product dimensions | 13,9 × 5,7 × 2,7 cm |
| Spalva | Mėlyna |
| Equipment / Configuration | 1 × sterile NIO Adult™ device, 1 × NIO Fixation™ securement dressing, instructions for use. |
OptiLube Lubricant, Box of 150
| Manufacturer | Optimum Medical |
|---|---|
| Model | OptiLube 5 g Lubricant, Box of 150 |
| Kilmės šalis | United Kingdom, United Kingdom |
| Gaminio tipas | Medical device, Medical device |
| Features | Sterile, water-soluble lubricating gel in single-use 5 g sachets. Reduces friction during medical procedures and is suitable for airway devices, catheters, and probes. Latex-free and easily rinsed off with water. Box contains 150 individually packaged sachets. |
| Sterility | Sterile |
| Certificates | ISO 13485 Manufacturer Quality Management System |
| Expiration date | Up to 5 years. |
| Usage | For assembling and replenishing kits in emergency services, training centres, and warehouses. Single-use. |
| Warnings | Single-use sachets. Do not use if the packaging is damaged or the product has expired. |
| Storage | Store in a dry place at room temperature. |
| Equipment / Configuration | 150 × sterile single-use OptiLube™ 5 g sachets. |
SWAT-T Elastic Tourniquet
| Manufacturer | Safeguard Medical Technologies Ltd. |
|---|---|
| Model | SWAT-T Tourniquet |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Dimensions: 10 × 137 cm (4″ × 54″); weight: approximately 113 g (4 oz); folded dimensions: approximately 11 × 7.6 cm; pressure indicator pattern; free from natural rubber latex; no mechanical components. |
| Certificates | Biocompatibility tested; MDR Declaration of Conformity. |
| Sterility | Non-sterile. |
| Expiration date | 10 years |
| Spalva | Juoda |
| Product dimensions | 142.2 × 10.2 cm (unstretched) |
| Equipment / Configuration | 1 × SWAT-T™ elastic tourniquet (black) |
| Usage | Bleeding control when a windlass tourniquet is unsuitable due to limb size. Can also be used as a pressure dressing or elastic bandage. |
| Warnings | When applied as a tourniquet, the application time must be recorded. Correct application technique is essential; appropriate training is recommended. |
| Storage | Store dry, protect from direct sunlight and ozone sources. |