Thermal Burn, Large
Self-adhesive wound simulation realistically replicating a large thermal burn. Designed for realistic first aid, emergency medicine, and tactical medicine training, as well as simulation scenarios.
For a better price—please send an inquiry
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW012-L |
| Country of origin | USA, USA |
| Product type | Teaching aid, Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Expiration date | No expiration date |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Equipment / Configuration | 1 × self-adhesive large thermal burn simulation (SW012-L). |
Description
The simulated thermal burn wound is designed for realistic first aid, emergency medicine, tactical medicine, and civil protection training. It helps create a realistic training environment where participants can practise casualty assessment, injury recognition, and emergency care skills.
The simulated wound is ready for immediate use – no additional adhesive, makeup, or other attachment materials are required. The self-adhesive backing allows it to be quickly and securely applied directly to the casualty simulator’s skin, making training preparation quick and straightforward.
The realistic appearance of a large thermal burn helps create more authentic training scenarios and encourages participants to make decisions under conditions that closely resemble real-life emergencies. Such practical simulations help develop not only technical skills but also the ability to perform under stress, communicate effectively as a team, and accurately assess a casualty’s condition.
According to the manufacturer, the simulated wound can be reused. After training, it can be removed and transferred from one casualty simulator to another without any additional preparation. If the adhesive surface becomes contaminated and loses adhesion, it is recommended to wash the simulated wound with warm soapy water. Once dry, the self-adhesive backing regains its adhesive properties and the wound is ready for reuse.
Thanks to its durability, ease of use, and realistic appearance, this simulated wound is a practical choice for training centres, healthcare institutions, universities, vocational training institutions, military organisations, uniformed services, and first aid instructors seeking to provide high-quality practical training.
Is adhesive needed?
No, the base is self-adhesive.
Can it be reused?
Yes – wash contaminated moulage with warm soapy water.
Suitable for real wounds?
No, this is a training aid only.
Technical Specifications
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW012-L |
| Country of origin | USA, USA |
| Product type | Teaching aid, Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Expiration date | No expiration date |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Equipment / Configuration | 1 × self-adhesive large thermal burn simulation (SW012-L). |
Similar products
Artzena First Aid Blanket, Silver and Green
| Manufacturer | Artzena |
|---|---|
| Model | ARZ5590 |
| Product type | Isothermal first-aid (rescue) blanket. |
| Features | Silver inner side and green outer side; lightweight and compact. |
| Sterility | Non-sterile. |
| Expiration date | 5 years. |
| Usage | Hypothermia prevention in outdoor, military, and tactical environments where reduced visibility is important. |
| Warnings | The foil blanket does not generate heat and provides significantly less protection than multilayer trauma blankets. |
| Storage | Store in a dry place in the original packaging. |
| Color | Sidabrinė, Žalia |
ATMIST Handover Cards
| Manufacturer | TSG Associates LLP |
|---|---|
| Model | 73806 |
| Country of origin | United Kingdom, United Kingdom |
| Product type | Ancillary aid, Ancillary aid |
| Features | Pre-printed ATMIST structure; fields for age, time, mechanism of injury, injuries, vital signs, and treatment. |
| Usage | Reusable for training purposes. |
| Warnings | The card is a documentation tool and does not replace medical records at the receiving healthcare facility. |
| Storage | Keep dry in a protected pouch. |
| Equipment / Configuration | 1 × ATMIST Handover / Triage Card |
HEMGUARD 4″ Targeted Pressure Bandage
| NSN | 6515-01-732-6982 |
|---|---|
| Manufacturer | 6:8 Medical Solutions LLC |
| Model | HEMGUARD 4″ Targeted Pressure Bandage |
| Country of origin | USA, USA |
| Product type | Medical device, Medical device |
| Features | Targeted pressure applicator; four-way strap routing; bidirectional mechanical advantage; weight approximately 113 g (4 oz); FDA listed and CE marked. |
| Certificates | U.S.-patented design. |
| Sterility | Sterile |
| Expiration date | 5 years |
| Usage | Neck, axillary, and groin wounds; amputations; maintaining pressure on packed wounds during evacuation. Single-use. |
| Warnings | The dressing does not replace a tourniquet in cases of life-threatening extremity bleeding. The wound must be properly packed before applying the dressing. |
| Storage | Store in a dry place in the original packaging. |
| Product dimensions | 10 cm (4″) × 163 cm (64″) |
| Color | Juoda |
| Equipment / Configuration | 1 × sterile HEMGUARD® 4″ pressure dressing in an individual vacuum-sealed package. |
| Package Dimensions | 11.4 × 24.8 × 3.8 cm (4.5 × 9.75 × 1.5 in) |
SAM IO Intraosseous Access System
| NSN | 6515-01-694-6094 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM IO Intraosseous Access System |
| Country of origin | USA, USA |
| Product type | Medical device, Medical device |
| Features | Manual operation without batteries; 15G needles in three lengths (15, 25, and 45 mm); standard Luer-lock connection; includes SAM Stabilizer and SAM Adapter. |
| Certificates | FDA 510(k) K191488 |
| Usage | Emergency vascular access when intravenous (IV) access cannot be established. Once the needle has been inserted into the bone marrow cavity, the stylet can be easily removed, providing access through a standard Luer-Lock connection. |
| Warnings | Intended for use by trained healthcare professionals only. Do not use on fractured or infected bone. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Color | Juoda |
| Contents | 1 × SAM IO Driver – manual intraosseous access system driver. |
SAM IO Stabilizer for Intraosseous Needles
| NSN | 6515-01-694-6043 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM IO Stabilizer, 1-pack |
| Country of origin | USA, USA |
| Product type | Medical device, Medical device |
| Features | Secures the needle to the limb; reduces the risk of displacement; compatible with the SAM IO system; supplied individually (1 unit). |
| Certificates | FDA GUDID registration; FDA Exempt seperate Premarket Submission. |
| Sterility | Sterile |
| Usage | Single-use |
| Warnings | Intended for use by trained healthcare professionals. After securing the needle, the access site must be checked regularly. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Equipment / Configuration | 1 × SAM IO Stabilizer (IO740-1P), individually sterile packaged. |
| Color | Skaidri |
