SAM Junctional Tourniquet for Inguinal and Axillary Bleeding
Junctional tourniquet with an AUTOSTOP buckle and two Target Compression Devices, designed to control life-threatening bleeding in the groin and axillary regions and to stabilise pelvic fractures.
For a better price—please send an inquiry
- Fast delivery throughout Lithuania and Europe
- Goods are stored and shipped from Lithuania
- Special Purchasing Terms for Businesses and Organizations
- Professional assistance from product selection to configuration
| NSN | 6515-01-618-7475 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM Junctional Tourniquet (SJT) |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Savvybės | AUTOSTOP buckle with audible confirmation at 150 N; 2 Target Compression Devices (TCDs); TCD extender; hand pump with auxiliary strap; application in less than 25 seconds. |
| Certificates | DA 510(k) K131561; EN ISO 13485:2016; ISO 13485:2016/MDSAP. |
| Sterility | Non-sterile |
| Product dimensions | Packed dimensions: 22.5 × 12.1 × 12.1 cm. |
| Usage | Bleeding from the groin or axillary regions; pelvic fracture immobilisation. Tactical medicine, emergency medical services, and military medicine. |
| Warnings | For use by trained professionals. Record the application time. Do not exceed the manufacturer’s specified application duration. |
| Storage | Store in a dry place in the original packaging. Protect the compression devices from puncture damage. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × SJT belt, 2 × Target Compression Devices (TCDs), 1 × TCD extender, 1 × hand pump, 1 × auxiliary strap, 1 × carrying case, instructions for use. |
Description
The SAM Junctional Tourniquet is a specialised bleeding control device designed to manage life-threatening haemorrhage in the groin and axillary regions where a conventional extremity tourniquet cannot be applied due to the location of the wound.
The device features a patented AUTOSTOP buckle that helps ensure proper initial belt tension before the targeted compression device is applied. Once a circumferential force of 150 N is reached, two indicator tabs automatically deploy from the buckle, accompanied by an audible click confirming proper application.
After eliminating belt slack, the inflatable Target Compression Device is inflated to apply focused pressure to the required anatomical area and control bleeding.
According to the manufacturer, the SAM Junctional Tourniquet can be applied in less than 25 seconds, making it suitable for situations where immediate intervention is required.
In addition to controlling junctional haemorrhage in the groin or axilla, the device can also be used to stabilise and immobilise pelvic fractures.
The SAM Junctional Tourniquet is intended for professional use in emergency, tactical, and military medicine where rapid and reliable bleeding control is required in anatomical areas where a standard extremity tourniquet cannot be applied.
How many compression devices are included?
The JT400-EN configuration includes 2 TCDs, 1 TCD extender, 1 hand pump and an auxiliary strap.
Does it work for pelvic fractures?
Yes, the manufacturer states a pelvic immobilisation function.
Technical Specifications
| NSN | 6515-01-618-7475 |
|---|---|
| Manufacturer | SAM Medical Products |
| Model | SAM Junctional Tourniquet (SJT) |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Savvybės | AUTOSTOP buckle with audible confirmation at 150 N; 2 Target Compression Devices (TCDs); TCD extender; hand pump with auxiliary strap; application in less than 25 seconds. |
| Certificates | DA 510(k) K131561; EN ISO 13485:2016; ISO 13485:2016/MDSAP. |
| Sterility | Non-sterile |
| Product dimensions | Packed dimensions: 22.5 × 12.1 × 12.1 cm. |
| Usage | Bleeding from the groin or axillary regions; pelvic fracture immobilisation. Tactical medicine, emergency medical services, and military medicine. |
| Warnings | For use by trained professionals. Record the application time. Do not exceed the manufacturer’s specified application duration. |
| Storage | Store in a dry place in the original packaging. Protect the compression devices from puncture damage. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × SJT belt, 2 × Target Compression Devices (TCDs), 1 × TCD extender, 1 × hand pump, 1 × auxiliary strap, 1 × carrying case, instructions for use. |
Similar products
6:8 Medical Advantage Pressure Bar Set
| Manufacturer | 6:8 Medical Solutions |
|---|---|
| Model | Advantage Pressure Bar Set (Popp Point Pressure Device, P3D) |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Medical device, Medical device |
| Features | Patented Popp Point Pressure Device (P3D) technology; pressure bar with three interchangeable heads; hands-free pressure; MOLLE- and pocket-compatible storage card; FDA listed, CE marked Class I device. |
| Certificates | FDA listed, CE marked. |
| Sterility | Non-sterile |
| Expiration date | 8 years. |
| Usage | Maintaining pressure on packed wounds at the neck, axilla, groin and extremities when the responder needs both hands free. |
| Warnings | This device maintains pressure and does not replace a tourniquet in life-threatening extremity bleeding. The wound must be properly packed first. |
| Storage | Store dry in the original packaging or on the supplied storage card. |
| Product dimensions | 12,7 × 9,5 × 3,8 cm (5″ × 3.75″ × 1.5″) |
| Spalva | Juoda |
| Equipment / Configuration | Pressure device; 3 pressure applicators in different sizes; storage card. |
Blizzard 3-Layer Thermal Cover BPS02
| NSN | 8465-99-433-4810 |
|---|---|
| Manufacturer | Blizzard Protection Systems (Safeguard Medical) |
| Model | Blizzard 3-Layer Thermal Blanket |
| Kilmės šalis | United Kingdom, United Kingdom |
| Gaminio tipas | Medical device, Medical device |
| Features | 3-layer Reflexcell construction; windproof and waterproof; reusable. |
| Certificates | UKCA, EU Declaration of Conformity (EU DoC), FDA GUDID. |
| Sterility | Non-sterile |
| Expiration date | Unlimited |
| Usage | Hypothermia management during prolonged evacuation and extended field care. |
| Warnings | The device reduces heat loss but does not generate heat. In cases of severe hypothermia, active warming methods are required. |
| Storage | Store in a dry place in the original packaging. |
| Product dimensions | Dimensions: Unpacked: 230 × 80 cm; Packed: 23 × 11 × 4 cm. |
| Spalva | Alyvuogių žalia juosta, balta pagalvėlė |
Piranha Tactical Shears, Small, Black
| NSN | 6515-01-538-9276 |
|---|---|
| Manufacturer | TyTek Medical |
| Model | Piranha Tactical Shears, Small |
| Kilmės šalis | USA, USA |
| Gaminio tipas | Ancillary aid, Ancillary aid |
| Features | Piranha® TM-705 are compact 5.5-inch (14 cm) tactical medical shears designed to military standards for use in confined spaces and individual first aid kits. High-quality stainless steel micro-serrated blades easily cut through thick clothing, leather, denim, straps, and other equipment while also providing precise cutting of softer materials such as gauze.Ergonomic handles with non-slip Kraton® rubber inserts provide a secure grip even when wearing gloves or working with wet hands, while the rounded lower blade helps reduce the risk of injury to the patient. Their compact size makes the shears convenient to carry in IFAK kits or medical vests. |
| Certificates | FDA registered; UDI labelled. |
| Sterility | Non-sterile. |
| Usage | Cutting clothing, straps, and bandages in first aid, emergency medical, and tactical medicine situations. Reusable. |
| Warnings | When cutting clothing, ensure that the blades do not come into contact with the casualty’s skin. Keep out of reach of children. |
| Storage | Store in a dry place; clean and dry after use. |
| Product dimensions | 14 cm (5,5″) long |
| Spalva | Juoda |
| Equipment / Configuration | 1 × Piranha® TM-705 tactical medical shears. |
TyTek Disposable Portable Manual Suction Unit
| NSN | 6515-01-540-7206 |
|---|---|
| Manufacturer | TyTek Medical |
| Model | Disposable Manual Suction Device. |
| Kilmės šalis | China, China |
| Gaminio tipas | Medical device, Medical device |
| Features | Compact, portable, single-use manual suction device designed for clearing the upper airway; mechanical operation without batteries or an electrical power source; vacuum pressure – approximately 110 mmHg; collection bag capacity – more than 1000 ml; one-way valves help prevent backflow of collected contents; silicone suction bulb; contoured suction tip; non-sterile; free from natural rubber latex. |
| Certificates | EU MDR 2017/745; FDA registruota medicinos priemonė / UDI 00855204008013. |
| Sterility | Non-sterile. |
| Usage | Clearing fluids and secretions from the airway in prehospital care when electric suction is unavailable. |
| Warnings | For use by trained responders. Limit suction duration to avoid interrupting ventilation and oxygen delivery. |
| Storage | Store in a dry place in the original packaging. |
| Spalva | Balta |
| Equipment / Configuration | 1 × TVAC TM-909 rankinis siurbimo įtaisas: silikoninė siurbimo kriaušė, integruotas standus plastikinis siurbimo vamzdelis su kontūriniu antgaliu, >1000 ml surinkimo maišelis su vienkrypčiais vožtuvais ir originali užsandarinama utilizavimo pakuotė su BIOHAZARD žymėjimu. |
Xtract SR Casualty Evacuation Stretcher
| NSN | 6530-99-315-5529 |
|---|---|
| Manufacturer | TSG Associates LLP |
| Model | Xtract SR Stretcher |
| Kilmės šalis | United Kingdom, United Kingdom |
| Gaminio tipas | Medical device, Medical device |
| Features | Weight: approximately 1 kg; load capacity: up to 300 kg; casualty positioning in approximately 30 seconds; Duralite fabric; drawcord and elastic securing system; graphical positioning markings; NSN 6530-99-315-5529. |
| Sterility | Non-sterile |
| Usage | Casualty evacuation from hazardous areas, including dragging, carrying, and transferring during military, rescue, and tactical operations. |
| Warnings | Inspect the condition of the fabric and seams before use. Do not exceed the manufacturer’s specified load capacity. Casualty handling and transfer should only be performed by trained personnel. |
| Storage | Store in a dry place, folded in the original carrying case. |
| Product dimensions | Unfolded stretcher dimensions: approximately 2500 × 900 mm (250 × 90 cm). |
| Spalva | Juoda |
| Equipment / Configuration | 1 × Xtract™ SR Stretcher textile evacuation stretcher. |