Showing 133–144 of 152 results
Third-Degree Chest Burn (Debrided)
For a better price—please send an inquiry
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW019-L |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Equipment / Configuration | 1 × SW019-L self-adhesive third-degree thermal chest burn simulation following debridement of damaged tissue. |
TMT Tactical Mechanical Tourniquet
For a better price—please send an inquiry
| NSN | 6515-01-656-6191 |
|---|---|
| Manufacturer | Safeguard Medical (manufactured by Alphapointe, USA) |
| Model | TMT Tactical Mechanical Tourniquet |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | 2-inch wide strap; dual-locking torsion mechanism; audible locking click; one-handed application; CoTCCC recommended; made in the USA. |
| Certificates | FDA GUDID registration; Berry Compliant version (31-115). |
| Sterility | Non-sterile |
| Expiration date | 7 years |
| Usage | Life-threatening bleeding from an arm or leg when a pressure dressing is insufficient. Tactical medicine, emergency medical services, and occupational safety. |
| Warnings | The tourniquet should only be applied in cases of life-threatening extremity bleeding. The application time must be recorded. It should only be removed by a medical professional. |
| Storage | Store in a dry place and protect from direct sunlight. |
| Product dimensions | Suitable for limbs with a circumference of 14.6–96.5 cm; packaged dimensions: 11.4 × 6.4 × 5.1 cm. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × tourniquet |
TOMManikin Base Training Mannequin
For a better price—please send an inquiry
| NSN | 6910-01-705-3108 |
|---|---|
| Manufacturer | Techline Technologies, Inc. |
| Model | Basic Manikin |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Reusable hyper-realistic trauma training manikin designed for TCCC, tactical medicine, mass-casualty, and emergency medical training; remote control via tablet; simulation of bleeding, breathing, pulse, and patient responses; integrated approximately 4.5 L simulated blood reservoir; replaceable limbs; supports training in tourniquet application, wound packing, airway management, needle decompression, chest tube insertion, and IV/IO access; durable steel frame and silicone skin; suitable for both classroom training and demanding field conditions. |
| Sterility | Non-sterile |
| Usage | Trauma management, first aid, and tactical medicine training in simulation centres and professional services. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Product dimensions | Manikin height: approximately 188 cm Manikin width: approximately 61 cm Manikin depth: approximately 25 cm |
| Equipment / Configuration | 1 × TOMManikin BASIC manekenas; NAR Simulation Advanced Remote Tablet su programine įranga; 1,2 gal. (~4,5 l) integruotas dirbtinio kraujo rezervuaras; Pelican 1500 priedų dėklas; 12 V 5 Ah ir 10 Ah NiMH akumuliatoriai su išmaniaisiais įkrovikliais; T formos įrankis ir skysčių jungtys; mokomoji uniforma su kontaktinėmis tvirtinimo juostomis; NAR IFAK; instruktoriaus Bluetooth ausinės; 2 transportavimo krepšiai su ratukais; TOMManikin naudojimo instrukcija. |
Torso Burn, Large
For a better price—please send an inquiry
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW014-L |
| Kilmės šalis | USA |
| Gaminio tipas | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Usage | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Product dimensions | Length: approximately 58.4 cm Width: approximately 40.6 cm |
| Equipment / Configuration | 1 × SW014-L large self-adhesive torso burn simulation. |
Triangular Bandage, Black
For a better price—please send an inquiry
| Manufacturer | NOBAMED Paul Danz AG |
|---|---|
| Model | Black Triangular Cloth Bandage. |
| Kilmės šalis | Germany |
| Gaminio tipas | Medical device |
| Features | The triangular cloth bandage is a versatile first aid item used to support an injured arm, immobilise fractures and dislocations, and secure dressings or splints. The soft viscose fabric is comfortable against the skin, durable, and easy to fold into different configurations depending on the type of injury.The black colour makes it particularly suitable for tactical medicine and use by military, police, and rescue services. The triangular bandage complies with DIN 13168 and is suitable for professional and individual first aid kits. |
| Certificates | Complies with DIN 13168 requirements; UDI labelled; compliant with EU MDR 2017/745. |
| Sterility | Non-sterile |
| Expiration date | 8 years from the date of manufacture. |
| Usage | Arm sling, securing dressings and splints, and improvised solutions in first aid situations. |
| Warnings | The triangular bandage is not intended as a primary bleeding control device. In cases of life-threatening bleeding, use a tourniquet or pressure dressing. |
| Storage | Store in a dry place in the original packaging. |
| Product dimensions | 96 × 96 × 136 cm. |
| Spalva | Juoda |
| Equipment / Configuration | 1 × triangular cloth bandage in individual packaging. |
Triangular Cloth Bandage, White
For a better price—please send an inquiry
| Manufacturer | ZARYS International Group |
|---|---|
| Model | White fabric triangular bandage. |
| Kilmės šalis | Poland |
| Gaminio tipas | Ancillary aid |
| Features | White fabric triangular bandage – multipurpose. |
| Certificates | EN ISO 13485 |
| Expiration date | 5 years. |
| Usage | Arm sling, securing dressings and splints in civilian first aid and training. |
| Warnings | The triangular bandage is not intended as a primary bleeding control device. In cases of life-threatening bleeding, use a tourniquet. |
| Storage | Store in a dry place in the original packaging. |
| Product dimensions | 96 × 96 × 136 cm |
| Spalva | Balta |
TSG Xtract SR Heatsaver Thermal Sleeping Bag
For a better price—please send an inquiry
| NSN | 6515-99-564-5689 |
|---|---|
| Manufacturer | TSG Associates LLP |
| Model | Xtract SR Heatsaver |
| Kilmės šalis | United Kingdom |
| Gaminio tipas | Medical device |
| Features | Passive hypothermia prevention and heat-retention system for trauma patients; reduces heat loss caused by conduction, convection, and environmental exposure; inflatable insulating mattress separates the patient from cold surfaces; shaped Heatseal cover provides thermal insulation around the body; EPS outer cover protects against wind and precipitation; packs compactly; weight approximately 2 kg; reusable; designed for use with the Xtract™ SR stretcher, but compatible with other stretcher systems. |
| Sterility | Non-sterile |
| Product dimensions | Packed system dimensions: approximately 37 × 18 cm. |
| Usage | Hypothermia prevention during evacuation, prolonged field care, and operations in cold environments. |
| Warnings | The device reduces heat loss but does not generate heat itself. |
| Storage | Store in a dry place in the original packaging. |
| Spalva | Žalia |
| Equipment / Configuration | 1 × Xtract™ SR Insulate inflatable insulating mattress; 1 × Xtract™ SR Heatseal thermal cover; 1 × Xtract™ SR EPS protective outer cover; 1 × Xtract™ SR Deployer transport/storage bag. |
Tvarstis Kraujavimui Stabdyti ”ChitoGauze® XR Pro” Safeguard
For a better price—please send an inquiry
| NSN | 6510-01-591-7740 |
|---|---|
| Manufacturer | Tricol Biomedical |
| Model | ChitoGauze XR Pro (Safeguard Medical distribution code PDF130) |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | Chitosan acetate-coated polyester and viscose gauze; X-ray detectable thread; Z-fold configuration; dimensions: 3″ × 4 yards (7.6 cm × 366 cm); CoTCCC approved; gamma sterilised. |
| Certificates | FDA 510(k) clearance (K153582); BAA compliant; TAA compliant. |
| Sterility | Sterile |
| Expiration date | 66 months |
| Usage | Single-use. Packing of deep wounds where a tourniquet cannot be applied, including the neck, axilla, and groin areas. Control of severe extremity bleeding when used in conjunction with a pressure dressing. |
| Warnings | For temporary external use only. Do not use in body cavities or on the eyes. The gauze should be removed by a healthcare professional. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Product dimensions | 7,5 cm × 3,7 m (3″ × 4 yd) |
| Spalva | Balta |
| Equipment / Configuration | 1 × sterile Z-fold ChitoGauze® XR Pro haemostatic gauze in vacuum-sealed packaging. |
TyTek Disposable Portable Manual Suction Unit
For a better price—please send an inquiry
| NSN | 6515-01-540-7206 |
|---|---|
| Manufacturer | TyTek Medical |
| Model | Disposable Manual Suction Device. |
| Kilmės šalis | China |
| Gaminio tipas | Medical device |
| Features | Compact, portable, single-use manual suction device designed for clearing the upper airway; mechanical operation without batteries or an electrical power source; vacuum pressure – approximately 110 mmHg; collection bag capacity – more than 1000 ml; one-way valves help prevent backflow of collected contents; silicone suction bulb; contoured suction tip; non-sterile; free from natural rubber latex. |
| Certificates | EU MDR 2017/745; FDA registruota medicinos priemonė / UDI 00855204008013. |
| Sterility | Non-sterile. |
| Usage | Clearing fluids and secretions from the airway in prehospital care when electric suction is unavailable. |
| Warnings | For use by trained responders. Limit suction duration to avoid interrupting ventilation and oxygen delivery. |
| Storage | Store in a dry place in the original packaging. |
| Spalva | Balta |
| Equipment / Configuration | 1 × TVAC TM-909 rankinis siurbimo įtaisas: silikoninė siurbimo kriaušė, integruotas standus plastikinis siurbimo vamzdelis su kontūriniu antgaliu, >1000 ml surinkimo maišelis su vienkrypčiais vožtuvais ir originali užsandarinama utilizavimo pakuotė su BIOHAZARD žymėjimu. |
TyTek PneumoDart Decompression Needle
For a better price—please send an inquiry
| NSN | 6515-01-655-9514 |
|---|---|
| Manufacturer | TyTek Medical |
| Model | PneumoDart 14G × 3.25″, Veress safety tip. |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | 14G × 3.25″ (approximately 8.25 cm); Veress safety tip; Luer-lock cap for active removal of air or blood; CoTCCC-recommended dimensions; NSN 6515-01-655-9514. |
| Certificates | FDA cleared; ISO 13485 certified. |
| Sterility | Sterile |
| Expiration date | 3 years. |
| Usage | Needle decompression for tension pneumothorax; management of chest trauma in emergency and tactical medical settings. |
| Warnings | For use by trained professionals only. Needle decompression should only be performed for tension pneumothorax in accordance with the applicable protocol. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Product dimensions | 14G x 3,25″ (apie 8,25 cm) |
| Spalva | Skaidri |
| Equipment / Configuration | 5 × 5 cm; hydrogel thickness: approximately 3.5 mm. |
TyTek TPAK 14G Decompression Needle
For a better price—please send an inquiry
| NSN | 6515-01-541-0635 |
|---|---|
| Manufacturer | TyTek Medical |
| Model | TPAK 14G x 3,25″Decompression needle. |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | 14G x 3,25″ (8,25 cm); CoTCCC Recommended dimensions; needle-free flash chamber for instant confirmation; |
| Certificates | FDA registration (GUDID), EU Declaration of Conformity (MDR), UDI labeling. |
| Sterility | Sterile |
| Usage | Needle decompression for tension pneumothorax in tactical and military medicine and emergency medical settings. Single-use.. |
| Warnings | For use by trained professionals only. Needle decompression should be performed only in cases of tension pneumothorax and in accordance with the applicable protocol. Immediate medical attention is required following the procedure.. |
| Storage | Store in a dry place at room temperature in the original packaging. |
| Product dimensions | 14G × 3,25″ (8,25 cm) |
| Spalva | Skaidri |
| Equipment / Configuration | 1 × sterile TPAK® TM-303 14G × 3.25” decompression needle with catheter in a protective case.. |
TyTek XTricate Lyte Soft Emergency Stretcher
For a better price—please send an inquiry
| Manufacturer | TyTek Medical |
|---|---|
| Model | XTricate Lyte Soft Emergency Stretcher |
| Kilmės šalis | USA |
| Gaminio tipas | Medical device |
| Features | Lightweight, compact, single-use soft emergency stretcher designed for rapid casualty transport; maximum load tested by an independent laboratory – 226 kg; made from durable polypropylene webbing and lightweight non-woven polypropylene fabric; reinforced polyester stitching; 4 large carrying handles on each side and 2 handles at both the head and foot ends, providing a total of 12 carrying handles. |
| Sterility | Non-sterile. |
| Usage | Rapid casualty transfer and extraction from hazardous areas in tactical, rescue, and industrial situations. |
| Warnings | Inspect the condition of the fabric and carrying handles before use. Casualty transfer should only be performed by trained personnel. |
| Storage | Store folded in a dry place. |
| Equipment / Configuration | 1 × XTricate Lyte TM-512 soft emergency stretcher. |